Callny G202 PLUS installationsguide
Komplett Callny G202 PLUS guide: nano SIM, koppling, alfanumeriska lösenord, auto-tilldelning, roller, timing.
Callny G202 PLUS (säljs även som Daniu GSM, LPSECURITY och CY305) är en av de mest populära GSM-grindöppnarmodulerna. Den använder nano-SIM istället för standard-SIM som RTU5024, stöder alfanumeriska lösenord upp till 12 tecken och har tre användarroller i G203-varianten. Men att hitta tydliga installationsinstruktioner på svenska är nästan omöjligt.
Vad gör Callny G202 annorlunda?
The Callny G202 PLUS is a GSM relay controller that opens gates via phone calls and SMS commands. According to the manufacturer documentation, it shares the same basic principle as the RTU5024 (authorized callers trigger a relay) but differs in several ways:
- Nano SIM instead of standard SIM (same format as modern phones)
- Alphanumeric passwords up to 12 characters (vs 4-digit RTU5024)
- Auto-assign user slots with the DEF command (vs manual slot assignment)
- Three user roles in the G203 variant: Super Admin (TOP), Admin (ADV), Normal (NOR)
- Delete by phone number as well as by slot (RTU5024 only deletes by slot)
Steg 1: Förbered nano-SIM
Insert a nano SIM into a phone, disable the PIN lock, verify voice and SMS work, and note the phone number. The Callny uses a nano SIM (the smallest format), which is the same size used by modern smartphones. No adapter needed.
Steg 2: Sätt i SIM och anslut ström
Power off, insert the nano SIM, connect 9-36V DC power to V+ and GND. Wait for the SIGNAL LED to stabilize (slow blink every 3 seconds = network registered).
Steg 3: Koppla reläet
Connect COM and NO to your gate motor's "open" button terminals. Same principle as RTU5024 wiring.
Steg 4: Lägg till ditt telefonnummer
The first authorized user automatically becomes the Super Admin (TOP). Send:
Command: {password}#TEL{phone}#DEF#
1234#TEL+31612345678#DEF# Response: Super User added, User ID:001
The DEF command auto-assigns the next available slot.
Steg 5: Ändra lösenordet
Default admin password is 1234. Change it to something stronger (up to 12 characters, letters and numbers):
Command: {password}#PWD#{new}#
1234#PWD#newpassword# Steg 6: Lägg till fler användare
Additional users are added as Admin (ADV) by default:
newpassword#TEL+31698765432#DEF# On the G203 variant, you can also add Normal users who can only call to open (no admin access):
newpassword#NORTEL+31655555555#DEF# Steg 7: Ställ in relätid
The Callny uses a different format than RTU5024. To set relay time to 5 seconds:
Command: {password}#GOT{seconds}#
newpassword#GOT005# Values range from 000 (toggle) to 999 seconds. Unlike the RTU5024's half-second increments, Callny values are in whole seconds.
Steg 8: Testa
Call the module's SIM number from an authorized phone. The gate should open.
Viktiga Callny-kommandon
| Command | Syntax | Example |
|---|---|---|
| Add user (auto-slot) | {pwd}#TEL{phone}#DEF# | 1234#TEL+316...#DEF# |
| Add user (specific slot) | {pwd}#TEL{phone}#{id}# | 1234#TEL+316...#003# |
| Add normal user (G203) | {pwd}#NORTEL{phone}#DEF# | 1234#NORTEL+316...#DEF# |
| Delete by slot | {pwd}#TEL#{id}# | 1234#TEL#002# |
| Delete by phone | {pwd}#DELTEL#{phone}# | 1234#DELTEL#+316...# |
| Query user | {pwd}#TEL{id}? | 1234#TEL001? |
| Change password | {pwd}#PWD#{new}# | 1234#PWD#mygate2026# |
| Set relay time | {pwd}#GOT{seconds}# | 1234#GOT005# |
| Relay ON | {pwd}#ON# | 1234#ON# |
| Relay OFF | {pwd}#OFF# | 1234#OFF# |
| Signal strength | {pwd}#CSQ? | 1234#CSQ? |
Callny vs RTU5024: viktiga skillnader
Feature Callny G202 PLUS RTU5024 SIM type Nano Standard Password Up to 12 chars, alphanumeric 4 digits only Auto-assign slots Yes (DEF command) No (manual slot number) Delete by phone number Yes (DELTEL) No (slot only) User roles (G203) TOP / ADV / NOR Single level Relay timing 0-999 seconds 0-9.5 seconds Price EUR 15-25 EUR 15-30
Skippa SMS-kommandona med GateOpener
GateOpener supports the Callny G202 PLUS and G203 alongside RTU5024. The app knows the Callny command syntax, handles the different password format, and shows user roles visually.
- Callny-specific features: auto-assign, delete by phone, user role display
- Multi-gate: manage Callny and RTU5024 modules from one app
- EUR 4.99 one-time, no subscription, no cloud
Get GateOpener
Vanliga frågor
Is the Callny G202 the same as the Daniu GSM or CY305?
Yes. The same hardware is sold under multiple brand names: Callny, Daniu GSM, LPSECURITY, CY305, and CN G202. The SMS commands are identical regardless of branding.
What's the difference between G202 PLUS and G203?
The G203 adds a third user role (Normal/NOR) for users who can only call to open but cannot manage other users. The G202 PLUS has two roles: Super Admin and Admin.
Can I use a standard SIM with an adapter?
No. The Callny's nano SIM slot is too small for an adapter. Use a nano SIM directly.
Källor
Manufacturer Documentation
Related Content
Redo att slippa SMS-kommandona?
GateOpener ersätter kryptiska koder med ett rent gränssnitt. En app för alla GSM-grindmoduler. Inget abonnemang, inget konto behövs.
Hämta GateOpenerRelaterade inlägg
Callny G202 SMS-kommandon: komplett referens
Komplett Callny G202 SMS-kommandoreferens: lösenord, roller, relä, KPON, GOT, åtkomst, aviseringar, signal.
Bästa GSM-grindöppnarmodulerna 2026: komplett jämförelse
RTU5024 vs Callny G202: användare, reläer, åtkomst, SIM, 4G, pris. Vilken modul passar dig?
Vilket SIM-kort fungerar bäst för GSM-grindöppnare?
SIM-kortsguide för GSM-grindöppnare: storlekar, kontantkort vs abonnemang, PIN, 2G-status och operatörsval.