The RTU5015 is a 2G GSM gate opener by King Pigeon. This page gives the facts and the SMS commands from its user guide (version 1.1, 2009), with the page where each one is.
The GateOpener app does not support this module.
Download the user guide
Download the RTU5015 user guide (PDF)- RTU5015 user guide, v1.1PDF, English, 0.6 MB
Specifications
| Default password | 1234 | page 6 |
|---|---|---|
| Maximum authorized numbers | 64 | pages 5 and 6 |
| Relay outputs | 1 (3A / 240VAC) | page 5 |
| Digital inputs | 2 | page 5 |
| Power supply | DC 12V, 1A | page 11 |
| GSM bands | 900/1800 MHz | page 11 |
| Operating temperature | -10 to +60 C | page 11 |
SMS commands from the user guide
Replace pwd with your password (default 1234). The guide asks for capital letters and no spaces (page 6). It also has commands for the two alarm inputs (sections 6.5 to 6.7, 6.11 and 6.14).
Change the password
Syntax:
pwd#PWDnew#PWDnew#Example:
1234#PWD6666#PWD6666#Guide section 6.1, page 6
Add an authorized number (positions 01-64)
Syntax:
pwd#TELnumber#position#Example:
1234#TEL13570810254#01#Guide section 6.2, page 6
Show the number at a position
Syntax:
pwd#TELposition?Example:
1234#TEL02?Guide section 6.3, page 7
Remove the number at a position
Syntax:
pwd#TEL#position?Example:
1234#TEL#12?Guide section 6.4, page 7
Let every caller open the gate
Syntax:
pwd#AA#Example:
1234#AA#Guide section 6.8, page 7
Only authorized numbers open the gate (default)
Syntax:
pwd#AU#Example:
1234#AU#Guide section 6.9, page 7
Relay close time, 0 to 9.5 seconds in steps of 0.5 (default 0.5 s; GOT19 is the maximum). GOT00 keeps the relay closed until the next call, and then only the 1st, 2nd and 3rd authorized numbers can reach the unit
Syntax:
pwd#GOTtime#Example:
1234#GOT19#Guide section 6.10, page 8
Show the relay close time
Syntax:
pwd#GOT?Example:
1234#GOT?Guide section 6.10, page 8
Check the GSM signal (0-32; above 12 to open reliably)
Syntax:
pwd#CSQ?Example:
1234#CSQ?Guide section 6.12, page 8
No confirmation SMS when the relay switches (default)
Syntax:
pwd#N#Example:
1234#N#Guide section 6.13, page 9
Modules the app supports
The modules the app works with are on the supported hardware page.