The DTM CONTROL 4G is a 2/4-channel GSM receiver by DTM System for gates and other automation, on 4G and 2G networks. A stored number opens a channel with a call: the receiver ends the call and switches the channel, and the manual says this connection is free (page 29). It also takes SMS commands (manual pages 3 and 29). This page gives its specifications and SMS commands, each with the page of the manual it comes from.
Status in the GateOpener app: The app does not support this module yet.
Download the manuals
The manufacturer's PDFs, as published:
- CONTROL 4G manual, 1.0 (2023-09-12)PDF, English, 19.5 MB
- CONTROL 4G leafletPDF, English, 2.4 MB
Specifications
| Item | Value and source |
|---|---|
| Default configuration password | admin, until the first administrator is added Source: CONTROL 4G manual 1.0, pages 9 and 10 |
| Phone numbers stored | 4,000, including 1 super administrator and 4 administrators Source: CONTROL 4G manual 1.0, page 3 |
| Relay outputs | 2, NO or NC, 1 A at 24 V AC or DC Source: CONTROL 4G manual 1.0, page 3 |
| Radio channels | 2 more with the optional 2CS (433 MHz) or 2CS868 (868 MHz) module Source: CONTROL 4G manual 1.0, pages 3 and 8 |
| Information inputs | 3, NO or NC Source: CONTROL 4G manual 1.0, page 3 |
| Output modes | Monostable, 1 to 65,535 s (call or SMS), or bistable (SMS only) Source: CONTROL 4G manual 1.0, pages 3 and 8 |
| Power supply | 12 to 24 V AC/DC ±10%, 500 mA Source: CONTROL 4G manual 1.0, page 3 |
| Mobile network | 4G and 2G; 700, 800, 900, 1800, 2100 and 2600 MHz Source: CONTROL 4G manual 1.0, page 3 |
| SIM card | Nano SIM, PIN off, voicemail off Source: CONTROL 4G manual 1.0, page 6 |
| Operating temperature | -20 to +55 °C Source: CONTROL 4G manual 1.0, page 3 |
| Housing / board | IP-54, 72 x 132 x 41 mm / 58 x 88 x 27 mm Source: CONTROL 4G manual 1.0, page 3 |
DTM also configures the receiver with its MEMO service programmer and MEMO MANAGER program for Windows, and with its own Android apps (manual pages 3 and 9).
To reset it to the factory settings, hold the RESET button on the board for 8 seconds. This deletes every stored number (manual page 8).
SMS commands from the manual
A configuration SMS starts with # and the password, then parameter=value pairs separated by commas: #password,sms1=1,clip1=0,time1=30. Parameter names may be upper or lower case; the password is case-sensitive (manual page 10).
Until an administrator is added, the password is admin and any number can configure the receiver. After that, only an administrator's number can (manual page 10). Most of the manual's examples below write #password: put your own password there (manual page 10).
Control SMS (OUTn, STATUS, GETCONFIG) need no # and no password, unless an SMS password is set: then the password and a dot come first (manual page 30). Write phone numbers with the country code, as +48123456789 or 0048123456789: a number without it is accepted but never recognised (manual pages 16 and 30).
Add an administrator (first one with the default password)
Adds a number with administrator rights and sets its configuration password (up to 16 letters and digits, case-sensitive). The SMS starts with #<password>, as every configuration SMS; until an administrator exists the password is admin. The first administrator must be the sender's own number (else ERROR: Set yourself as an admin first) and becomes super administrator. At most 5 administrators in all. Add CLIPn=1 to the same SMS to let the administrator open channel n by call: ADD switches off every right it does not name.
ADD={phone},VIP="{newpwd}"ADD=user_number,VIP="password"Give a stored user administrator rights
Makes a stored user an administrator with his own configuration password.
#{pwd},MOD={phone},VIP="{newpwd}"#password,MOD=48123456789,VIP="stefek70"Remove administrator rights
The number stays stored as a subscriber. An administrator cannot remove his own rights; the super administrator cannot be modified by an administrator.
#{pwd},MOD={phone},VIP=""#stefek70,MOD=48987654321,VIP=""Add users
Adds 1 to 20 numbers, comma separated, with the rights that follow: CLIPn=1 (open channel n by call, monostable channels only), SMSn=1 (open channel n by SMS OUTn), STATUSn=1 (read information input n, inputs 1-3). A right not named is OFF. More than 20 numbers adds none. A number already stored is skipped. A multiple ADD sends no welcome SMS and cannot add administrators.
#{pwd},ADD={phones},{rights}#password,ADD=48123456789,48123456789,CLIP1=1,SMS2=1,STATUS1=1Change a user's rights
Sets the named rights (CLIPn, SMSn, STATUSn, INnACT, INnDEACT, VIP) of one stored number; rights not named stay as they are.
#{pwd},MOD={phone},{rights}#password,MOD=48123456789,clip1=0,sms1=1Change the rights of all users
Sets the named rights of every stored number. VIP and administrator-only rights cannot be changed this way. An administrator changes everyone except the super administrator.
#{pwd},MODALL,{rights}#password,MODALL,clip1=0,sms1=1Delete a user
Removes one number from the memory.
#{pwd},DEL={phone}#password,DEL=48123456789Delete all administrators
Super administrator only.
#{pwd},DELADMINS#password,DELADMINSReplace a user's number
Changes a stored number and keeps its rights.
#{pwd},REP={oldphone},{newphone}#password,REP=48123456789,48987654321Delete all users
Removes every stored number.
#{pwd},DELALL#password,DELALLRead a user's rights
Returns the settings of one stored number. The manual does not print the reply text.
#{pwd},GET={phone}#password,GET=48123456789Read the receiver settings
Returns control methods, channel modes, input types, reply settings, the number of subscribers and administrators, and the firmware version (Frm = x, page 9). The manual does not print the reply text.
#{pwd},GET#password,GETRead the channel and input names
Returns the user-friendly names of the outputs and inputs.
#{pwd},GETNAMES#password,GETNAMESSet the pulse time of channel n
Monostable mode: the relay of channel n (1 or 2) closes for 1-65535 seconds. 0 sets bistable mode (next entry). Channels 3 and 4 of the radio module are fixed at 1 s.
#{pwd},TIME{n}={seconds}#password,TIME1=20Set channel n to bistable
Channel n (1 or 2) stays on until switched off. A bistable channel cannot be opened by call, only by SMS OUTnON / OUTnOFF.
#{pwd},TIME{n}=0#password,TIME1=0Name output n
Channels 1-4, up to 20 characters without diacritics or special signs.
#{pwd},NameOUT{n}="{name}"#password,NameOUT1 ="Entrance gate"Switch channel n off
Channels 1-4. The channel no longer reacts to any control.
#{pwd},STOP{n}=1#password,STOP1=1Switch channel n on
Channels 1-4.
#{pwd},STOP{n}=0#password,STOP1=0Input n normally open
Information inputs 1-3.
#{pwd},TYPE{n}=NO#password,TYPE1=NOInput n normally closed
Information inputs 1-3.
#{pwd},TYPE{n}=NC#password,TYPE1=NCName input n
Information inputs 1-3, up to 20 characters without diacritics or special signs.
#{pwd},NameIn{n}="{name}"#password,NameIn1= "Gate status"Text when input n turns active
Up to 60 characters. Only administrators receive input notifications. SmsONn="" restores the default text (INn = ON).
#{pwd},SmsON{n}="{text}"#password,SmsON1= "Gate open"Text when input n turns inactive
Up to 60 characters. Only administrators receive input notifications. SmsOFFn="" restores the default text (INn = OFF).
#{pwd},SmsOFF{n}="{text}"#password,SmsOFF1= "Gate closed"Status reply after each control SMS on
After each control SMS the receiver texts the state of its inputs and outputs, instead of OK. On at the factory (page 9).
#{pwd},AutoStatus=1#password,AutoStatus=1Status reply after each control SMS off
No status text after a control SMS.
#{pwd},AutoStatus=0#password,AutoStatus=0OK / ERROR reply after each control SMS on
After each control SMS the receiver texts OK or an ERROR line. Without AutoAck or AutoStatus a control SMS gets no reply.
#{pwd},AutoAck=1#password,AutoAck=1OK / ERROR reply after each control SMS off
No OK / ERROR text after a control SMS.
#{pwd},AutoAck=0#password,AutoAck=0Language of the welcome SMS
PL, EN or DE.
#{pwd},LANG={lang}#password,LANG=ENWelcome SMS to new users on
A user added alone gets an SMS from the receiver with his control methods and a link to DTM's Android widget. On at the factory. Also needed for STATUS and GETCONFIG.
#{pwd},UserNotify=1#password,UserNotify=1Welcome SMS to new users off
No welcome SMS. It also blocks the STATUS and GETCONFIG commands and DTM's status widget.
#{pwd},UserNotify=0#password,UserNotify=0Silent mode on
No reply to configuration SMS; only GET, GETNAMES, GETAUTO and GET=<number> still answer (page 33).
#{pwd},Silent=1#password,Silent=1Silent mode off
Configuration SMS are answered again.
#{pwd},Silent=0#password,Silent=0Guests may open channel n by call
Any caller (a number not stored) opens monostable channel n; with ClipPass set, the guest types the code and # after a tone. Of channels 3 and 4 only channel 3 can be called. Off at the factory. Without MOD= this sets the guest right, not a user's.
#{pwd},CLIP{n}=1#password,CLIP1=1Guests may not open channel n by call
Only stored numbers with CLIPn=1 open channel n by call.
#{pwd},CLIP{n}=0#password,CLIP1=0Guests may open channel n by SMS
Any sender may send OUTn (or password.OUTn when SmsPass is set). Guests get no reply SMS.
#{pwd},SMS{n}=1#password,SMS1=1Guests may not open channel n by SMS
Only stored numbers with SMSn=1 open channel n by SMS.
#{pwd},SMS{n}=0#password,SMS1=0Guest code for calls
Digits only, up to 16. ClipPass="" removes it.
#{pwd},ClipPass="{code}"#password,ClipPass="123"Guest password for control SMS
Letters and digits, up to 16. Control SMS then read password.OUTn. SmsPass="" removes it.
#{pwd},SmsPass="{code}"#password,SmsPass="abc123"Factory reset
Restores factory settings and deletes every stored number; the password is admin again. Holding RESET for 8 seconds does the same (page 8).
#{pwd},Format=0417#password,Format=0417Automatic adding on
For up to 48 hours, every number that texts the 4-digit PIN to the receiver is stored with the given rights.
#{pwd},AUTOADD={pin},time={hours},{rights}#password,AUTOADD=1234,time=12,clip1=1,sms1=1,status1=1Automatic adding off
Ends the automatic adding mode.
#{pwd},AUTOADD=0#password,AUTOADD=0Read the automatic adding settings
Returns the automatic adding mode settings.
#{pwd},GETAUTO#password,GETAUTOOpen channel n by SMS
Sent from a stored number with SMSn=1. Channels 1-4, monostable mode. Case does not matter (the manual's announcements use out1). The SMS is charged at the operator's rate.
OUT{n}OUT1Switch bistable channel n on
Channels 1 and 2 in bistable mode (TIMEn=0) only.
OUT{n}ONOUT1ONSwitch bistable channel n off
Channels 1 and 2 in bistable mode (TIMEn=0) only.
OUT{n}OFFOUT1OFFStatus of inputs and outputs
The reply shows only what the sender's rights allow. Does not work with UserNotify=0. The manual does not print the reply text.
STATUSSTATUSMy control methods
Lists the control methods the sender has. Does not work with UserNotify=0.
GETCONFIGGETCONFIGControl SMS with an SMS password
When an SMS control password (SmsPass) is set, the control command follows the password and a dot.
{smspwd}.{command}abc123.out1Modules the app supports