RTU5024 SMS-commando's
22 commando's. Tik op de kopieerknop om het voorbeeldcommando te kopiëren en plak het in je SMS-app.
Standaardwachtwoord: 1234
Initialize (REQUIRED first step)
adminRegister the module's SIM card number. This is the FIRST command you must send. Use 00 prefix instead of +.
Syntax
{pwd}TEL{moduleSIM}# Voorbeeld
1234TEL00861351015# Antwoord
Set Success! Syntax
{pwd}TEL{moduleSIM}# Voorbeeld
1234TEL00861351015# Antwoord
Set Success! Sync clock
adminSet the module's internal clock. Required for time-limited users to work correctly.
Syntax
{pwd}T{YYMMDDHHmm}# Voorbeeld
1234T2603291530# Antwoord
Set Time OK! Syntax
{pwd}T{YYMMDDHHmm}# Voorbeeld
1234T2603291530# Antwoord
Set Time OK! Change password
adminChange device password to new 4-digit password.
Syntax
{pwd}P{newpwd} Voorbeeld
1234P6666 Antwoord
Password changed to {newpwd}, please remember it carefully. Syntax
{pwd}P{newpwd} Voorbeeld
1234P6666 Antwoord
Password changed to {newpwd}, please remember it carefully. Add permanent user
adminAdd authorized user to slot (001-200). Always allowed to call and control.
Syntax
{pwd}A{slot}#{phone}# Voorbeeld
1234A003#123456# Antwoord
User added confirmation Syntax
{pwd}A{slot}#{phone}# Voorbeeld
1234A003#123456# Antwoord
User added confirmation Add time-limited user
adminAdd user with access limited to a date/time range. Clock must be synced first.
Syntax
{pwd}A{slot}#{phone}#{startYYMMDDHHmm}#{endYYMMDDHHmm}# Voorbeeld
1234A016#123456#1502050800#1502051000# Antwoord
User added confirmation Syntax
{pwd}A{slot}#{phone}#{startYYMMDDHHmm}#{endYYMMDDHHmm}# Voorbeeld
1234A016#123456#1502050800#1502051000# Antwoord
User added confirmation Query user by slot
adminCheck which phone number is stored at a position.
Syntax
{pwd}A{slot}# Voorbeeld
1234A002# Antwoord
Phone number at slot or Empty Syntax
{pwd}A{slot}# Voorbeeld
1234A002# Antwoord
Phone number at slot or Empty Batch query users
adminQuery authorized numbers from slot range. Returns multiple SMS (10 numbers per SMS).
Syntax
{pwd}AL{slotStart}#{slotEnd}# Voorbeeld
1234AL002#050# Antwoord
List of users across multiple SMS Syntax
{pwd}AL{slotStart}#{slotEnd}# Voorbeeld
1234AL002#050# Antwoord
List of users across multiple SMS Delete user
adminRemove authorized number at position (or overwrite with new number).
Syntax
{pwd}A{slot}## Voorbeeld
1234A002## Antwoord
User deleted Syntax
{pwd}A{slot}## Voorbeeld
1234A002## Antwoord
User deleted Allow all callers
adminAllow any phone number to trigger the relay. WARNING: free access for anyone.
Syntax
{pwd}ALL# Voorbeeld
1234ALL# Antwoord
Allow all mode set Syntax
{pwd}ALL# Voorbeeld
1234ALL# Antwoord
Allow all mode set Authorized users only (default)
adminOnly authorized numbers can trigger the relay. Recommended setting.
Syntax
{pwd}AUT# Voorbeeld
1234AUT# Antwoord
Authorized only mode set Syntax
{pwd}AUT# Voorbeeld
1234AUT# Antwoord
Authorized only mode set Set relay close time
adminHow long relay stays closed (ON) after call. 000=0.5s latch, 001-998=seconds, 999=stays on until next call.
Syntax
{pwd}GOT{seconds}# Voorbeeld
1234GOT030# Antwoord
Relay time set Syntax
{pwd}GOT{seconds}# Voorbeeld
1234GOT030# Antwoord
Relay time set Configure relay ON SMS
adminSet who receives SMS when relay turns ON and what it says. a=first user (0/1), b=caller (0/1).
Syntax
{pwd}GON{ab}#{content}# Voorbeeld
1234GON11#DoorOpen# Antwoord
Confirmation set Syntax
{pwd}GON{ab}#{content}# Voorbeeld
1234GON11#DoorOpen# Antwoord
Confirmation set Configure relay OFF SMS
adminSet who receives SMS when relay turns OFF and what it says.
Syntax
{pwd}GOFF{ab}#{content}# Voorbeeld
1234GOFF00#DoorClose# Antwoord
Confirmation set Syntax
{pwd}GOFF{ab}#{content}# Voorbeeld
1234GOFF00#DoorClose# Antwoord
Confirmation set Disable relay ON SMS
adminNo SMS notification when relay turns ON.
Syntax
{pwd}GON## Voorbeeld
1234GON## Antwoord
ON notification disabled Syntax
{pwd}GON## Voorbeeld
1234GON## Antwoord
ON notification disabled Disable relay OFF SMS
adminNo SMS notification when relay turns OFF.
Syntax
{pwd}GOFF## Voorbeeld
1234GOFF## Antwoord
OFF notification disabled Syntax
{pwd}GOFF## Voorbeeld
1234GOFF## Antwoord
OFF notification disabled Relay ON (by SMS)
all authorizedTurn relay on via SMS command. Close time follows GOT setting.
Syntax
{pwd}CC Voorbeeld
1234CC Antwoord
Relay ON (or custom GON content) Syntax
{pwd}CC Voorbeeld
1234CC Antwoord
Relay ON (or custom GON content) Relay OFF (by SMS)
all authorizedTurn relay off via SMS command.
Syntax
{pwd}DD Voorbeeld
1234DD Antwoord
Relay OFF (or custom GOFF content) Syntax
{pwd}DD Voorbeeld
1234DD Antwoord
Relay OFF (or custom GOFF content) Check status
all authorizedQuery relay state, signal strength, and device info.
Syntax
{pwd}EE Voorbeeld
1234EE Antwoord
Relay status, GSM signal value, firmware info Syntax
{pwd}EE Voorbeeld
1234EE Antwoord
Relay status, GSM signal value, firmware info Set auto-report interval
adminAuto-send status report to first user every X hours. 000=disabled (default).
Syntax
{pwd}T#{hours}# Voorbeeld
1234T#024# Antwoord
Auto-report set Syntax
{pwd}T#{hours}# Voorbeeld
1234T#024# Antwoord
Auto-report set Query auto-report interval
adminCheck current auto-report interval.
Syntax
{pwd}T# Voorbeeld
1234T# Antwoord
Current interval in hours Syntax
{pwd}T# Voorbeeld
1234T# Antwoord
Current interval in hours Query IMEI and firmware
adminGet the module's IMEI code and firmware version.
Syntax
{pwd}IMEI# Voorbeeld
1234IMEI# Antwoord
IMEI and firmware info Syntax
{pwd}IMEI# Voorbeeld
1234IMEI# Antwoord
IMEI and firmware info Factory reset
physical button or SMSReset to factory settings. Authorized users are preserved. Can also hold reset button on device.
Syntax
RESET Voorbeeld
RESET Antwoord
Device restarts Syntax
RESET Voorbeeld
RESET Antwoord
Device restarts