# Waferstar GSM-KEY user manual

> Waferstar GSM-KEY manual (DC200 and AC2000): default password 123456, 200 or 2,000 users, the SMS commands with the manual page of each, and both PDFs.

Canonical: https://gate-opener.app/manuals/waferstar-gsm-key/

Last reviewed: November 16, 2026

![Waferstar GSM-KEY module, front](https://gate-opener.app/images/hardware/waferstar-gsm-key-front-transparent.png)

The Waferstar GSM-KEY is a board with a GSM modem that opens an electric gate. When a number on its white list calls, it rejects the call and clicks the relay. The manual says this costs nothing,

**Status in the GateOpener app:** The app does not support this module yet.

## Download the manuals

The manufacturer's PDFs, as published:

- [GSM-KEY AC2000 manual, 3.2](https://gate-opener.app/manuals/GSM-KEY-AC2000-manual.pdf) PDF, English, 1.0 MB
- [GSM-KEY-DC DC200 manual, 3.1](https://gate-opener.app/manuals/GSM-KEY-DC200-manual.pdf) PDF, English, 0.7 MB

## Specifications

| Item | Value and source |
| --- | --- |
| Default password | 123456 (6 digits) Source: DC200 manual 3.1, pages 4 and 5 |
| Regular user numbers | DC200: 200. AC2000: 2,000 Source: DC200 manual 3.1, page 2; AC2000 manual 3.2, page 2 |
| Time-limited numbers (DC200) | 50 by weekday and time, 50 by date range, 550 by number of uses Source: DC200 manual 3.1, page 2 |
| Alarm numbers | 5 Source: DC200 manual 3.1, page 2 |
| Alarm inputs | 2 Source: DC200 manual 3.1, page 2 |
| Relay terminals | NC1, COM1, NO1 for the gate; NO2, COM2 Source: DC200 manual 3.1, page 2 (text and connector photo) |
| Relay contact rating (AC2000) | 48 V, 0.5 A at most Source: AC2000 manual 3.2, page 3 |
| Gate pulse at the factory | 300 ms Source: DC200 manual 3.1, page 6 |
| Phone numbers | At most 10 digits, no country code Source: DC200 manual 3.1, page 5 |
| Mobile network | GSM; dual-band or quad-band by country Source: DC200 manual 3.1, page 12 |
| Power (AC2000) | 220 V mains Source: AC2000 manual 3.2, page 3 |

The commands below are from the DC200 manual. The AC2000 manual has the same command names, but some of its examples write the slot with other digits (WHL01 instead of WHL001); check yours against its own PDF.

Each command gets a reply SMS: OK when it is correct, Err when it is not (DC200 manual page 4).

## SMS commands from the manual

Every command starts with #PWD and the 6-digit password; replace 123456 with yours (DC200 manual pages 4 and 5).

Store phone numbers without the country code, at most 10 digits. If your number is longer, the manual tells you to enter its rightmost 10 digits (DC200 manual page 5).

### Change password

Change device password. Must enter new password twice.

Syntax: `#PWD{pwd}#CAP{newpwd}#CAP{newpwd}`

In the manual: `#PWD123456#CAP333444#CAP333444`

Reply: PWD SETUP OK

Source: DC200 manual 3.1, page 5

### Add permanent user (WHL)

Add permanent user to whitelist slot (1-200). Max 10 digit phone number, strip country code.

Syntax: `#PWD{pwd}#WHL{slot}={phone}`

In the manual: `#PWD123456#WHL001=61143815`

Reply: WHL01 SET TO 61143815 OK

Source: DC200 manual 3.1, page 5

### Query permanent user slot

Check which phone is in a permanent slot

Syntax: `#PWD{pwd}#WHL{slot}?`

In the manual: `#PWD123456#WHL001?`

Reply: WHL001 IS 61143815 OK

Source: DC200 manual 3.1, page 5

### Delete permanent user

Remove user from permanent whitelist (or overwrite with new number)

Syntax: `#PWD{pwd}#WHL{slot}=0000000`

In the manual: `#PWD123456#WHL001=0000000`

Reply: WHL001 SET TO 00000000

Source: DC200 manual 3.1, page 5

### List all permanent users (PC only)

List all numbers in the whitelist. Only works via PC software, not SMS.

Syntax: `#PWD{pwd}#WHL=ALL?`

In the manual: `#PWD123456#WHL=ALL?`

Reply: WHL001 IS XXX WHL003 IS XXX ...

Source: DC200 manual 3.1, page 5

### Add weekly schedule user (SHL)

Add user with weekly day+time schedule. Days: 1=Mon..7=Sun. 50 slots.

Syntax: `#PWD{pwd}#SHL{slot}={phone}:{days}({startTime}-{endTime})`

In the manual: `#PWD123456#SHL001=13564121668:1357(8:32-23:59)`

Source: DC200 manual 3.1, page 6

### Add date-range user (PHL)

Add user with access limited to a date range and daily time window. 50 slots. Date format: YYMMDD.

Syntax: `#PWD{pwd}#PHL{slot}={phone}:{startDate}-{endDate}({startTime}-{endTime})`

In the manual: `#PWD123456#PHL001=13564121668:100324-101012(8:32-18:26)`

Source: DC200 manual 3.1, page 6

### Add count-limited user (QHL)

Add user with limited number of uses. Expires after {count} activations. 550 slots.

Syntax: `#PWD{pwd}#QHL{slot}={phone}:{count}`

In the manual: `#PWD123456#QHL001=13564121668:12`

Source: DC200 manual 3.1, page 6

### Query special list user (SHL/PHL/QHL)

Check which phone is in a special list slot. Replace {type} with SHL, PHL, or QHL.

Syntax: `#PWD{pwd}#{type}{slot}?`

In the manual: `#PWD123456#SHL0001?`

Reply: SHL01 IS 61143815 OK

Source: DC200 manual 3.1, page 6

### Delete special list user (SHL/PHL/QHL)

Remove user from a special list slot. Replace {type} with SHL, PHL, or QHL.

Syntax: `#PWD{pwd}#{type}{slot}=0000`

In the manual: `#PWD123456#PHL01=0000`

Source: DC200 manual 3.1, page 6

### List all special users (PC only)

List all numbers in special lists. Only works via PC software.

Syntax: `#PWD{pwd}#SHL=ALL?`

In the manual: `#PWD123456#SHL=ALL?`

Reply: SHL01 IS XXX QHL08 IS XXX ...

Source: DC200 manual 3.1, page 6

### Set relay delay (gate pulse time)

Set relay pulse duration in MILLISECONDS. Default is 300ms.

Syntax: `#PWD{pwd}#GOT{milliseconds}`

In the manual: `#PWD123456#GOT500`

Reply: DELAY TIME SET TO 0500MS

Source: DC200 manual 3.1, page 6

### Query relay delay

Check current relay delay setting

Syntax: `#PWD{pwd}#GOT?`

In the manual: `#PWD123456#GOT?`

Reply: DELAY TIME IS 0500 MS

Source: DC200 manual 3.1, page 6

### Set relay mode - Momentary pulse

Set relay to momentary pulse mode (click and release). Default mode.

Syntax: `#PWD{pwd}#MODE0`

In the manual: `#PWD123456#MODE0`

Reply: RELAY SET TO MODE0

Source: DC200 manual 3.1, page 8

### Set relay mode - Ratchet/toggle

Set relay to ratchet/toggle mode (stays on until next call toggles it off)

Syntax: `#PWD{pwd}#MODE1`

In the manual: `#PWD123456#MODE1`

Reply: RELAY SET TO MODE1

Source: DC200 manual 3.1, page 8

### Check signal strength

Query GSM signal quality (0-32). Above 12 is usable, above 16 is good.

Syntax: `#PWD{pwd}#CSQ?`

In the manual: `#PWD123456#CSQ?`

Reply: CSQ IS 26

Source: DC200 manual 3.1, page 8

### Check status

Full device status including alarm config, relay delay, user count, signal, relay state.

Syntax: `#PWD{pwd}#STATUS?`

In the manual: `#PWD123456#STATUS?`

Reply: ALARM1=ON:SMS:10,ALARM2=ON:SMS:20,GOT=1000,WHL=85,ALARM1=H,ALARM2=H,BCPW=34,CSQ=20,RELAY=ON

Source: DC200 manual 3.1, page 8

### Add alarm phone number

Add phone number to receive alarm notifications (max 5 numbers)

Syntax: `#PWD{pwd}#ALARM{slot}={phone}`

In the manual: `#PWD123456#ALARM01=13818120592`

Reply: ALARM01 SET TO 61143815 OK

Source: DC200 manual 3.1, page 7

### Query alarm phone number

Check which phone is in an alarm slot

Syntax: `#PWD{pwd}#ALARM{slot}?`

In the manual: `#PWD123456#ALARM01?`

Reply: ALARM01 IS 61143815 OK

Source: DC200 manual 3.1, page 7

### List all alarm numbers

List all alarm notification numbers

Syntax: `#PWD{pwd}#ALARM=ALL?`

In the manual: `#PWD123456#ALARM=ALL?`

Reply: ALARM IS XXXXX:XXXX:XXXXXXX:0000:0000

Source: DC200 manual 3.1, page 7

### Configure alarm inputs

Configure alarm input behavior. State: ON/OFF. Mode: SMS or PHONE. Duration: seconds the input must be held to trigger.

Syntax: `#PWD{pwd}#ALARM-IN1={state}:{mode}:{duration},ALARM-IN2={state}:{mode}:{duration}`

In the manual: `#PWD123456#ALARM-IN1=ON:SMS:2,ALARM-IN2=ON:PHONE:3`

Reply: ALARM\_IN1=ON:SMS:2, ALARM\_IN2=ON:PHONE:3

Source: DC200 manual 3.1, page 7

### Set alarm SMS text

Configure custom SMS text sent when alarm inputs are triggered

Syntax: `#PWD{pwd}#UDI1:{text1},UDI2:{text2}`

In the manual: `#PWD123456#UDI1:XXXXXX, UDI2:XXXXXX`

Source: DC200 manual 3.1, page 7

### Set timer-update phone number

Designate which phone number can update the device clock (required for SHL/PHL time features)

Syntax: `#PWD{pwd}#TIMER-UPDATE:{phone}`

In the manual: `#PWD123456#TIMER-UPDATE: 96754667`

Reply: #PWD123456#TIMER-UPDATE: 96754667 OK

Source: DC200 manual 3.1, page 8

### Sync device clock

Update the device's internal clock. Must be sent from the designated timer-update phone number.

Syntax: `#PWD{pwd}#CLOCK`

In the manual: `#PWD123456#CLOCK`

Reply: CLOCK UPDATE TO 2010-10-18,16:58:10

Source: DC200 manual 3.1, page 8

## Modules the app supports

The modules the app works with are on the [supported hardware](https://gate-opener.app/hardware/) page. Their manuals are on the [manuals](https://gate-opener.app/manuals/) page.