# DTM CONTROL 4G user manual

> DTM CONTROL 4G manual: a 2/4-channel 4G and 2G GSM receiver for 4,000 numbers. Default password admin, the SMS commands with the manual page of each, and the PDFs.

Canonical: https://gate-opener.app/manuals/dtm-control-4g/

Last reviewed: November 16, 2026

The DTM CONTROL 4G is a 2/4-channel GSM receiver by DTM System for gates and other automation, on 4G and 2G networks. A stored number opens a channel with a call: the receiver ends the call and switches the channel, and the manual says this connection is free (page 29). It also takes SMS commands (manual pages 3 and 29). This page gives its specifications and SMS commands, each with the page of the manual it comes from.

**Status in the GateOpener app:** The app does not support this module yet.

## Download the manuals

The manufacturer's PDFs, as published:

- [CONTROL 4G manual, 1.0 (2023-09-12)](https://gate-opener.app/manuals/CONTROL4G-manual-en-v1.0-2023-09-12.pdf) PDF, English, 19.5 MB
- [CONTROL 4G leaflet](https://gate-opener.app/manuals/CONTROL4G-leaflet-en.pdf) PDF, English, 2.4 MB

## Specifications

| Item | Value and source |
| --- | --- |
| Default configuration password | admin, until the first administrator is added Source: CONTROL 4G manual 1.0, pages 9 and 10 |
| Phone numbers stored | 4,000, including 1 super administrator and 4 administrators Source: CONTROL 4G manual 1.0, page 3 |
| Relay outputs | 2, NO or NC, 1 A at 24 V AC or DC Source: CONTROL 4G manual 1.0, page 3 |
| Radio channels | 2 more with the optional 2CS (433 MHz) or 2CS868 (868 MHz) module Source: CONTROL 4G manual 1.0, pages 3 and 8 |
| Information inputs | 3, NO or NC Source: CONTROL 4G manual 1.0, page 3 |
| Output modes | Monostable, 1 to 65,535 s (call or SMS), or bistable (SMS only) Source: CONTROL 4G manual 1.0, pages 3 and 8 |
| Power supply | 12 to 24 V AC/DC ±10%, 500 mA Source: CONTROL 4G manual 1.0, page 3 |
| Mobile network | 4G and 2G; 700, 800, 900, 1800, 2100 and 2600 MHz Source: CONTROL 4G manual 1.0, page 3 |
| SIM card | Nano SIM, PIN off, voicemail off Source: CONTROL 4G manual 1.0, page 6 |
| Operating temperature | -20 to +55 °C Source: CONTROL 4G manual 1.0, page 3 |
| Housing / board | IP-54, 72 x 132 x 41 mm / 58 x 88 x 27 mm Source: CONTROL 4G manual 1.0, page 3 |

DTM also configures the receiver with its MEMO service programmer and MEMO MANAGER program for Windows, and with its own Android apps (manual pages 3 and 9).

To reset it to the factory settings, hold the RESET button on the board for 8 seconds. This deletes every stored number (manual page 8).

## SMS commands from the manual

A configuration SMS starts with # and the password, then parameter=value pairs separated by commas: #password,sms1=1,clip1=0,time1=30. Parameter names may be upper or lower case; the password is case-sensitive (manual page 10).

Until an administrator is added, the password is admin and any number can configure the receiver. After that, only an administrator's number can (manual page 10). Most of the manual's examples below write #password: put your own password there (manual page 10).

Control SMS (OUTn, STATUS, GETCONFIG) need no # and no password, unless an SMS password is set: then the password and a dot come first (manual page 30). Write phone numbers with the country code, as +48123456789 or 0048123456789: a number without it is accepted but never recognised (manual pages 16 and 30).

### Add an administrator (first one with the default password)

Adds a number with administrator rights and sets its configuration password (up to 16 letters and digits, case-sensitive). The SMS starts with #\<password>, as every configuration SMS; until an administrator exists the password is admin. The first administrator must be the sender's own number (else ERROR: Set yourself as an admin first) and becomes super administrator. At most 5 administrators in all. Add CLIPn=1 to the same SMS to let the administrator open channel n by call: ADD switches off every right it does not name.

Syntax: `ADD={phone},VIP="{newpwd}"`

In the manual: `ADD=user_number,VIP="password"`

Reply: SUCCESSFULLY ADDED, or OK (n params); ERROR: Set yourself as an admin first; ERROR: No more VIP available

The manual prints this line without "#password," (page 10). Every configuration SMS starts with it: the manual's example on that page begins "# admin, ADD = 48123456789".

Source: CONTROL 4G manual 1.0, page 10

### Give a stored user administrator rights

Makes a stored user an administrator with his own configuration password.

Syntax: `#{pwd},MOD={phone},VIP="{newpwd}"`

In the manual: `#password,MOD=48123456789,VIP="stefek70"`

Reply: SUCCESSFULLY MODIFIED, or OK (n params); ERROR: No more VIP available; ERROR: Does not exist

Source: CONTROL 4G manual 1.0, page 17

### Remove administrator rights

The number stays stored as a subscriber. An administrator cannot remove his own rights; the super administrator cannot be modified by an administrator.

Syntax: `#{pwd},MOD={phone},VIP=""`

In the manual: `#stefek70,MOD=48987654321,VIP=""`

Reply: SUCCESSFULLY MODIFIED, or OK (n params); ERROR: Currently, you can not delete / modify yourself. Try from another admin; ERROR: You can not delete / modify super admin

Source: CONTROL 4G manual 1.0, page 10

### Add users

Adds 1 to 20 numbers, comma separated, with the rights that follow: CLIPn=1 (open channel n by call, monostable channels only), SMSn=1 (open channel n by SMS OUTn), STATUSn=1 (read information input n, inputs 1-3). A right not named is OFF. More than 20 numbers adds none. A number already stored is skipped. A multiple ADD sends no welcome SMS and cannot add administrators.

Syntax: `#{pwd},ADD={phones},{rights}`

In the manual: `#password,ADD=48123456789,48123456789,CLIP1=1,SMS2=1,STATUS1=1`

Reply: SUCCESSFULLY ADDED, or OK (n params); ERROR: Already exists; ERROR: Memory full; ERROR: You can specify max. 20 numbers

Source: CONTROL 4G manual 1.0, page 16

### Change a user's rights

Sets the named rights (CLIPn, SMSn, STATUSn, INnACT, INnDEACT, VIP) of one stored number; rights not named stay as they are.

Syntax: `#{pwd},MOD={phone},{rights}`

In the manual: `#password,MOD=48123456789,clip1=0,sms1=1`

Reply: SUCCESSFULLY MODIFIED, or OK (n params); ERROR: Does not exist; ERROR: No subscribers

Source: CONTROL 4G manual 1.0, page 16

### Change the rights of all users

Sets the named rights of every stored number. VIP and administrator-only rights cannot be changed this way. An administrator changes everyone except the super administrator.

Syntax: `#{pwd},MODALL,{rights}`

In the manual: `#password,MODALL,clip1=0,sms1=1`

Reply: MODIFIED ALL (super administrator) or MODIFIED ALL EXCEPT SUPERADMIN (administrator)

Source: CONTROL 4G manual 1.0, page 17

### Delete a user

Removes one number from the memory.

Syntax: `#{pwd},DEL={phone}`

In the manual: `#password,DEL=48123456789`

Reply: SUBSCRIBER DELETED; ERROR: Does not exist

Source: CONTROL 4G manual 1.0, page 17

### Delete all administrators

Super administrator only.

Syntax: `#{pwd},DELADMINS`

In the manual: `#password,DELADMINS`

Reply: ALL ADMINS DELETED EXCEPT YOU

Source: CONTROL 4G manual 1.0, page 17

### Replace a user's number

Changes a stored number and keeps its rights.

Syntax: `#{pwd},REP={oldphone},{newphone}`

In the manual: `#password,REP=48123456789,48987654321`

Reply: OK (n params) or an ERROR line

Source: CONTROL 4G manual 1.0, page 17

### Delete all users

Removes every stored number.

Syntax: `#{pwd},DELALL`

In the manual: `#password,DELALL`

Reply: ALL SUBSCRIBERS DELETED

Source: CONTROL 4G manual 1.0, page 17

### Read a user's rights

Returns the settings of one stored number. The manual does not print the reply text.

Syntax: `#{pwd},GET={phone}`

In the manual: `#password,GET=48123456789`

Reply: Settings of the number (format not in the manual); ERROR: Does not exist

Source: CONTROL 4G manual 1.0, page 17

### Read the receiver settings

Returns control methods, channel modes, input types, reply settings, the number of subscribers and administrators, and the firmware version (Frm = x, page 9). The manual does not print the reply text.

Syntax: `#{pwd},GET`

In the manual: `#password,GET`

Reply: Settings summary (format not in the manual)

Source: CONTROL 4G manual 1.0, page 15

### Read the channel and input names

Returns the user-friendly names of the outputs and inputs.

Syntax: `#{pwd},GETNAMES`

In the manual: `#password,GETNAMES`

Reply: Names (format not in the manual)

Source: CONTROL 4G manual 1.0, page 15

### Set the pulse time of channel n

Monostable mode: the relay of channel n (1 or 2) closes for 1-65535 seconds. 0 sets bistable mode (next entry). Channels 3 and 4 of the radio module are fixed at 1 s.

Syntax: `#{pwd},TIME{n}={seconds}`

In the manual: `#password,TIME1=20`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 11

### Set channel n to bistable

Channel n (1 or 2) stays on until switched off. A bistable channel cannot be opened by call, only by SMS OUTnON / OUTnOFF.

Syntax: `#{pwd},TIME{n}=0`

In the manual: `#password,TIME1=0`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 11

### Name output n

Channels 1-4, up to 20 characters without diacritics or special signs.

Syntax: `#{pwd},NameOUT{n}="{name}"`

In the manual: `#password,NameOUT1 ="Entrance gate"`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 11

### Switch channel n off

Channels 1-4. The channel no longer reacts to any control.

Syntax: `#{pwd},STOP{n}=1`

In the manual: `#password,STOP1=1`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 11

### Switch channel n on

Channels 1-4.

Syntax: `#{pwd},STOP{n}=0`

In the manual: `#password,STOP1=0`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 11

### Input n normally open

Information inputs 1-3.

Syntax: `#{pwd},TYPE{n}=NO`

In the manual: `#password,TYPE1=NO`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 11

### Input n normally closed

Information inputs 1-3.

Syntax: `#{pwd},TYPE{n}=NC`

In the manual: `#password,TYPE1=NC`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 11

### Name input n

Information inputs 1-3, up to 20 characters without diacritics or special signs.

Syntax: `#{pwd},NameIn{n}="{name}"`

In the manual: `#password,NameIn1= "Gate status"`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 12

### Text when input n turns active

Up to 60 characters. Only administrators receive input notifications. SmsONn="" restores the default text (INn = ON).

Syntax: `#{pwd},SmsON{n}="{text}"`

In the manual: `#password,SmsON1= "Gate open"`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 12

### Text when input n turns inactive

Up to 60 characters. Only administrators receive input notifications. SmsOFFn="" restores the default text (INn = OFF).

Syntax: `#{pwd},SmsOFF{n}="{text}"`

In the manual: `#password,SmsOFF1= "Gate closed"`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 12

### Status reply after each control SMS on

After each control SMS the receiver texts the state of its inputs and outputs, instead of OK. On at the factory (page 9).

Syntax: `#{pwd},AutoStatus=1`

In the manual: `#password,AutoStatus=1`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 13

### Status reply after each control SMS off

No status text after a control SMS.

Syntax: `#{pwd},AutoStatus=0`

In the manual: `#password,AutoStatus=0`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 13

### OK / ERROR reply after each control SMS on

After each control SMS the receiver texts OK or an ERROR line. Without AutoAck or AutoStatus a control SMS gets no reply.

Syntax: `#{pwd},AutoAck=1`

In the manual: `#password,AutoAck=1`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 13

### OK / ERROR reply after each control SMS off

No OK / ERROR text after a control SMS.

Syntax: `#{pwd},AutoAck=0`

In the manual: `#password,AutoAck=0`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 13

### Language of the welcome SMS

PL, EN or DE.

Syntax: `#{pwd},LANG={lang}`

In the manual: `#password,LANG=EN`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 13

### Welcome SMS to new users on

A user added alone gets an SMS from the receiver with his control methods and a link to DTM's Android widget. On at the factory. Also needed for STATUS and GETCONFIG.

Syntax: `#{pwd},UserNotify=1`

In the manual: `#password,UserNotify=1`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 13

### Welcome SMS to new users off

No welcome SMS. It also blocks the STATUS and GETCONFIG commands and DTM's status widget.

Syntax: `#{pwd},UserNotify=0`

In the manual: `#password,UserNotify=0`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 14

### Silent mode on

No reply to configuration SMS; only GET, GETNAMES, GETAUTO and GET=\<number> still answer (page 33).

Syntax: `#{pwd},Silent=1`

In the manual: `#password,Silent=1`

The manual prints no reply text. It says the mode will "disable SMS to the administrator after the configuration command" (page 14).

Source: CONTROL 4G manual 1.0, page 14

### Silent mode off

Configuration SMS are answered again.

Syntax: `#{pwd},Silent=0`

In the manual: `#password,Silent=0`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 14

### Guests may open channel n by call

Any caller (a number not stored) opens monostable channel n; with ClipPass set, the guest types the code and # after a tone. Of channels 3 and 4 only channel 3 can be called. Off at the factory. Without MOD= this sets the guest right, not a user's.

Syntax: `#{pwd},CLIP{n}=1`

In the manual: `#password,CLIP1=1`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 14

### Guests may not open channel n by call

Only stored numbers with CLIPn=1 open channel n by call.

Syntax: `#{pwd},CLIP{n}=0`

In the manual: `#password,CLIP1=0`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 14

### Guests may open channel n by SMS

Any sender may send OUTn (or password.OUTn when SmsPass is set). Guests get no reply SMS.

Syntax: `#{pwd},SMS{n}=1`

In the manual: `#password,SMS1=1`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 14

### Guests may not open channel n by SMS

Only stored numbers with SMSn=1 open channel n by SMS.

Syntax: `#{pwd},SMS{n}=0`

In the manual: `#password,SMS1=0`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 14

### Guest code for calls

Digits only, up to 16. ClipPass="" removes it.

Syntax: `#{pwd},ClipPass="{code}"`

In the manual: `#password,ClipPass="123"`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 15

### Guest password for control SMS

Letters and digits, up to 16. Control SMS then read password.OUTn. SmsPass="" removes it.

Syntax: `#{pwd},SmsPass="{code}"`

In the manual: `#password,SmsPass="abc123"`

Reply: OK (n params)

Source: CONTROL 4G manual 1.0, page 15

### Factory reset

Restores factory settings and deletes every stored number; the password is admin again. Holding RESET for 8 seconds does the same (page 8).

Syntax: `#{pwd},Format=0417`

In the manual: `#password,Format=0417`

Reply: DATA CLEANED

Source: CONTROL 4G manual 1.0, page 16

### Automatic adding on

For up to 48 hours, every number that texts the 4-digit PIN to the receiver is stored with the given rights.

Syntax: `#{pwd},AUTOADD={pin},time={hours},{rights}`

In the manual: `#password,AUTOADD=1234,time=12,clip1=1,sms1=1,status1=1`

Reply: AUTOADD ON (with details)

Source: CONTROL 4G manual 1.0, page 19

### Automatic adding off

Ends the automatic adding mode.

Syntax: `#{pwd},AUTOADD=0`

In the manual: `#password,AUTOADD=0`

Reply: AUTOADD OFF

Source: CONTROL 4G manual 1.0, page 19

### Read the automatic adding settings

Returns the automatic adding mode settings.

Syntax: `#{pwd},GETAUTO`

In the manual: `#password,GETAUTO`

Reply: Settings (format not in the manual)

Source: CONTROL 4G manual 1.0, page 19

### Open channel n by SMS

Sent from a stored number with SMSn=1. Channels 1-4, monostable mode. Case does not matter (the manual's announcements use out1). The SMS is charged at the operator's rate.

Syntax: `OUT{n}`

In the manual: `OUT1`

Reply: OK only with AutoAck=1; the status text with AutoStatus=1; ERROR: Command not available without the right

Source: CONTROL 4G manual 1.0, page 30

### Switch bistable channel n on

Channels 1 and 2 in bistable mode (TIMEn=0) only.

Syntax: `OUT{n}ON`

In the manual: `OUT1ON`

Reply: OK only with AutoAck=1; the status text with AutoStatus=1

Source: CONTROL 4G manual 1.0, page 30

### Switch bistable channel n off

Channels 1 and 2 in bistable mode (TIMEn=0) only.

Syntax: `OUT{n}OFF`

In the manual: `OUT1OFF`

Reply: OK only with AutoAck=1; the status text with AutoStatus=1

Source: CONTROL 4G manual 1.0, page 30

### Status of inputs and outputs

The reply shows only what the sender's rights allow. Does not work with UserNotify=0. The manual does not print the reply text.

Syntax: `STATUS`

In the manual: `STATUS`

Reply: Status text (format not in the manual)

Source: CONTROL 4G manual 1.0, page 30

### My control methods

Lists the control methods the sender has. Does not work with UserNotify=0.

Syntax: `GETCONFIG`

In the manual: `GETCONFIG`

Reply: Control methods text (format not in the manual)

Source: CONTROL 4G manual 1.0, page 30

### Control SMS with an SMS password

When an SMS control password (SmsPass) is set, the control command follows the password and a dot.

Syntax: `{smspwd}.{command}`

In the manual: `abc123.out1`

Reply: As the command itself

Source: CONTROL 4G manual 1.0, page 30

## Modules the app supports