RTU5024 SMS-Befehle

22 Befehle. Tippe auf den Kopieren-Button, um den Beispielbefehl zu kopieren, und füge ihn in deine SMS-App ein.

Hinweis: Commands use NO # delimiters (unlike Callny). Password is 4 digits. Up to 200 authorized numbers (positions 001-200). Commands must be CAPS LOCK. Device will NOT reply if command is invalid (for security).

Standardpasswort: 1234

Initialize (REQUIRED first step)

admin

Register the module's SIM card number. This is the FIRST command you must send. Use 00 prefix instead of +.

Syntax

{pwd}TEL{moduleSIM}#

Beispiel

1234TEL00861351015#

Antwort

Set Success!

Sync clock

admin

Set the module's internal clock. Required for time-limited users to work correctly.

Syntax

{pwd}T{YYMMDDHHmm}#

Beispiel

1234T2603291530#

Antwort

Set Time OK!

Change password

admin

Change device password to new 4-digit password.

Syntax

{pwd}P{newpwd}

Beispiel

1234P6666

Antwort

Password changed to {newpwd}, please remember it carefully.

Add permanent user

admin

Add authorized user to slot (001-200). Always allowed to call and control.

Syntax

{pwd}A{slot}#{phone}#

Beispiel

1234A003#123456#

Antwort

User added confirmation

Add time-limited user

admin

Add user with access limited to a date/time range. Clock must be synced first.

Syntax

{pwd}A{slot}#{phone}#{startYYMMDDHHmm}#{endYYMMDDHHmm}#

Beispiel

1234A016#123456#1502050800#1502051000#

Antwort

User added confirmation

Query user by slot

admin

Check which phone number is stored at a position.

Syntax

{pwd}A{slot}#

Beispiel

1234A002#

Antwort

Phone number at slot or Empty

Batch query users

admin

Query authorized numbers from slot range. Returns multiple SMS (10 numbers per SMS).

Syntax

{pwd}AL{slotStart}#{slotEnd}#

Beispiel

1234AL002#050#

Antwort

List of users across multiple SMS

Delete user

admin

Remove authorized number at position (or overwrite with new number).

Syntax

{pwd}A{slot}##

Beispiel

1234A002##

Antwort

User deleted

Allow all callers

admin

Allow any phone number to trigger the relay. WARNING: free access for anyone.

Syntax

{pwd}ALL#

Beispiel

1234ALL#

Antwort

Allow all mode set

Authorized users only (default)

admin

Only authorized numbers can trigger the relay. Recommended setting.

Syntax

{pwd}AUT#

Beispiel

1234AUT#

Antwort

Authorized only mode set

Set relay close time

admin

How long relay stays closed (ON) after call. 000=0.5s latch, 001-998=seconds, 999=stays on until next call.

Syntax

{pwd}GOT{seconds}#

Beispiel

1234GOT030#

Antwort

Relay time set

Configure relay ON SMS

admin

Set who receives SMS when relay turns ON and what it says. a=first user (0/1), b=caller (0/1).

Syntax

{pwd}GON{ab}#{content}#

Beispiel

1234GON11#DoorOpen#

Antwort

Confirmation set

Configure relay OFF SMS

admin

Set who receives SMS when relay turns OFF and what it says.

Syntax

{pwd}GOFF{ab}#{content}#

Beispiel

1234GOFF00#DoorClose#

Antwort

Confirmation set

Disable relay ON SMS

admin

No SMS notification when relay turns ON.

Syntax

{pwd}GON##

Beispiel

1234GON##

Antwort

ON notification disabled

Disable relay OFF SMS

admin

No SMS notification when relay turns OFF.

Syntax

{pwd}GOFF##

Beispiel

1234GOFF##

Antwort

OFF notification disabled

Relay ON (by SMS)

all authorized

Turn relay on via SMS command. Close time follows GOT setting.

Syntax

{pwd}CC

Beispiel

1234CC

Antwort

Relay ON (or custom GON content)

Relay OFF (by SMS)

all authorized

Turn relay off via SMS command.

Syntax

{pwd}DD

Beispiel

1234DD

Antwort

Relay OFF (or custom GOFF content)

Check status

all authorized

Query relay state, signal strength, and device info.

Syntax

{pwd}EE

Beispiel

1234EE

Antwort

Relay status, GSM signal value, firmware info

Set auto-report interval

admin

Auto-send status report to first user every X hours. 000=disabled (default).

Syntax

{pwd}T#{hours}#

Beispiel

1234T#024#

Antwort

Auto-report set

Query auto-report interval

admin

Check current auto-report interval.

Syntax

{pwd}T#

Beispiel

1234T#

Antwort

Current interval in hours

Query IMEI and firmware

admin

Get the module's IMEI code and firmware version.

Syntax

{pwd}IMEI#

Beispiel

1234IMEI#

Antwort

IMEI and firmware info

Factory reset

physical button or SMS

Reset to factory settings. Authorized users are preserved. Can also hold reset button on device.

Syntax

RESET

Beispiel

RESET

Antwort

Device restarts
GateOpener holen